After pressing the knob again, you will see the start screen.

Press and hold the knurled knob for 2-3 seconds. The display should now show "Z: +0.2".

Turn the knurled know clockwise. This will cause the x-axis to move upwards.

Move the x-axis all the way up against the top mounts to make sure the x-axis is parallel to the bed.

This will produce a loud noise, which is normal.

Check whether both sides are touching the top mounts. If this is not the case, check to see why there is a blockage.

By turning the knob counterclockwise, you now move the axis down 3-4cm.

Press the knurled knob once to display the start screen.